In a standard underfloor heating system, hydronic balancing is a very difficult and laborious process. The solution is an unique and innovative product! The THB23030 has two temperature sensors that are connected between the Auto Balancing Actuator: the emitter flow & return pipes or the inlet and outlet of the manifold.
Product advantages:
- Easy to install on the manifold
- Quarantees efficient heating even at different loop lengths
- Has 2 contact sensors for measuring the flow and return temperature in the heating loop
- Short opening time (about 30 seconds)
- Consumes a small amount of power (less than 0,5 W)
Technical specifications:
- Power supply: 230V AC 50 Hz
- Power consumption: 0,5 W
- Opening time: 30 seconds
- Protection class: IP54
- Thread's size: M30 x 1.5
- Dimension [mm]: 93 x 38 x 54
- Power cord length [cm]: 93
- Sensor cord length [cm]: 45
Self-regulating actuator THB23030 has two temperature sensors that are installed on the supply and return of the appropriate floor heating loop. It measures the temperature on the sensors and adjusts its operation to maintain the correct temperature difference between supply and return (ΔT).
The following figure shows the difference in operation of a standard thermoelectric actuator compared to the SALUS THB23030 self-regulating actuator :
See in detail how to operate the THB23030 self-regulating thermoelectric actuator in the video below: